FMEA Info Centre

Everything you want to know about Failure Mode and Effect Analysis
Home
Contact
Search
Site Map

Search News Alerts Latest Updates Community Examples Guides and Introductions Handbooks
Books Papers Abstracts Presentations Services Standards Tools


 


Other FMEA
 Sources

 

Title: Dependability Evaluation of Substation Automation System with Redundancy

Author: Ito, H; Kaneda, K; Hamamatsu, K; Tanaka, T; Nara, K
Abstract: Substation Automation Systems (SAS) are widely used for the purpose of control, protection, monitoring, communication etc. in substations to improve the reliability of the power supply. SASs adopting IT based solutions such as Ethernet LAN have recently become more common although hardwired control has been used in the past in earlier versions of SAS utilising simple communication methods. Moreover, IEC 61850 which is the international standard for communications within substations has been published, and the application of SAS based on IEC 61850 is increasing. It is necessary to select each component and the configuration of the SAS from the viewpoint of dependability so that the dependability of the SAS, i.e. reliability, availability, and serviceability may have a very big impact in the stability of the power supply in the electric power transmission and distribution systems. In this paper, we will describe the configuration policy of an IEC 61850 based SAS, its actual system configuration and the redundant configuration to improve dependability. In addition, we will explain some of the new functions not currently covered by IEC 61850 that we have developed to improve usability and availability. Following which we will present an evaluation of the dependability for MTTF (Mean Time To Failure), Availability, and FMEA (Failure Mode and Effects Analysis) for these configurations of SAS based on the dependability requirements for SAS.
Source: NEW ASPECTS OF SYSTEMS, PTS I AND II
Publication Year: 2008
Volume:
Issue nr:
Pages: 713 - 721
Science Code: Operations Research & Management Science
Tags: SAS; Substation Automation System; IEC 61850; Reliability; Dependability; Availability; System Architecture; Redundant System


1978- 1993

 fmea_abstract_abstracts_1.htm

- 1997

fmea_abstract_abstracts_2.htm

- 1999

fmea_abstract_abstracts_3.htm

- 2000

fmea_abstract_abstracts_4.htm

- 2002

fmea_abstract_abstracts_5.htm

- 2004

fmea_abstract_abstracts_6.htm

- 2004 cnd

fmea_abstract_abstracts_7.htm

- 2005

fmea_abstract_abstracts_8.htm

- 2006

fmea_abstract_abstracts_9.htm

- 2007

fmea_abstract_abstracts_10.htm

- 2008

fmea_abstract_abstracts_11.htm

- 2008 cnd

fmea_abstract_abstracts_12.htm

- 2009

fmea_abstract_abstracts_13.htm

- 2009 cnd

fmea_abstract_abstracts_14.htm

Add a link Recommend this site Link to this site About this site Status

FMEA Info Centre

All you want to know about Failure Mode and Effect Analysis
Home
Contact
Search
Site Map